Basic Info.
Certification
RoHS, CCC, ISO9001, CE
Working Medium
R410A or R407c
Heat Source Type
Air Source Heat Pump
Transport Package
Standard Export Package
Product Description
-- Product Description --
Withair® packaged rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, "no-strip screw" collars, and handled access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with environmentally (R-410A) refrigerant and are factory tested. Withair® packaged rooftop unit applicability is wide and used in shopping malls, hotels, factories, villas, commercial housing, office buildings, shops, hospitals and other places.
-- The Key Advantages Include --
All model sizes share a common, compact cabinet in a single footprint for on-site flexibility.
Installation time and costs are reduced by easy power and control wiring. All units are factory-wired, charged and tested prior to shipment.
Gas and electric utility knockouts are provided on unit side and bottom for easy connections.
Compressor is internally protected against high pressure and temperature.
Units are engineered and built to be among the quietest models.
Full-perimeter base rails are easily removable, yet provide a solid unit foundation.
Durable finish, made of powder-painted, galvanized steel to meet 500-hour salt-spray test demands.
Condensate drain is heavy-duty. 3/4" NPT connection is rigidly mounted for a proper fit and a tight seal.
Condensate pan is non-corrosive, long-lasting and watertight.
Convertible airflow design means no panel cutting is required, and no accessory panel is necessary.
Heat exchangers are corrosion-resistant, with aluminized steel tubular construction for durability and long service life.
Post-purge induced draft combustion exhausts combustion products from the heat exchanger to prolong heat exchanger life.
Hot surface to pilot ignition provides faster, more reliable heat delivery.
Secured service access ports are protected, externally mounted and reusable on both high and low lines.
Complete line of field-installed accessories, including propane and high altitude conversion kits, economizers, single- and dual-enthalpy sensors and more.
Evaporator coils are constructed with grooved copper tubes and enhanced for construction to improve heat transfer.
Condenser coils are constructed of MicroChannel aluminum tubing and aluminum fins for durability and long-lasting efficient operation.
Cooling operating range up to 52°C and down to -1°C.
Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement.
Access panels with easy grip handles and tool-less filter access door
Belt drive evaporator-fan motor and pulley combinations available on all three phase models to meet any application
Field convertible from vertical to horizontal airflow for slab mounting.
Dependable time/temperature defrost board and logic.
Loss of charge, freeze protection, and high-pressure switches
Totally enclosed condenser motors with permanently lubricated bearings.
Permanently lubricated evaporator-fan motor.
1. Multi-compressors system - provide up to 4 grades of refrigeration capacity regulation, optional variable capacity digital scroll compressor can further improve the equipment energy saving and control accuracy.
2. Double layer board gold structure -- polyamine foam double layer board gold structure pioneered by yilong.The highest thermal resistance in the industry is 2.8m2ºC/w.
3. Electronic expansion valve - provides the most accurate superheat control (1ºC) while reducing equipment failure rate.
4. Controller - optional PLC programmable controller improves field control adaptability and makes network connection faster.
5. Heat exchanger - the world's first oval tube heat exchanger to greatly improve the energy saving level.
6. Reheater (optional) - reheat is provided through waste heat of condenser without electric heating.
7. Heat recovery wheel (optional) - there are two options, sensible heat and total heat, to absorb the energy in the exhaust air.
8. Enthalpy difference controller (optional) - when the outdoor enthalpy value is lower than the indoor enthalpy value, the compressor is closed and the outdoor natural air is utilized cooling room environment.
9. Secondary air return (side) - humidity control through secondary air return is the most energy-saving humidity control solution.
10. Gas heating (optional) - gas heating can be used in winter to provide stable heating.
11. High efficiency fan motor - straight connected vortex free case backward tilt fan greatly improves fan efficiency.
12. Types selection - air - cooled type or water - cooled type for option.
Withair's patent: Air volume and compressor capacity automatically matching
Withair's Rooftop Unit can provide up to 7 levels of air volume regulation, greatly improving the energy efficiency of the equipment.For example, when indoor load is low, only one compressor is working, at this time, the air supply volume will be automatically reduced to 15-20% of the total air volume to achieve the energy saving goal.
When the indoor load increases, for example, two compressors are needed to put into operation, the air supply will automatically increase to match the cooling capacity.
-- The Directions of Air Supply & Air Inlet --
Multiple optional air supply methods, so that Withair Rooftop air conditioner can adapt to a variety of building conditions.
Whether indoor or outdoor, whether the roof or the ground, it can be a good design layout.
-- Rapid Product Customization Services --
Customer's personalized demand for Rooftop Unit is the design concept of Withair. our each Rooftop Unit can be customized according
to the customer's special requirements.Our engineers will quickly design each personalized roof machine, including the structure, function
and control can be customized.
Packaged Rooftop Unit
Model W05R1- | | 41RF | 55RF | 65RF | 76RF | 85RF | 95RF | 112RF | 130RF | 156RF | 188RF | 211RF | 228RF | 261RF | 352RF |
Rated cooling capacity | kW | 41.1 | 55.3 | 64.7 | 75.8 | 85.3 | 94.7 | 112.6 | 129.5 | 155.8 | 187.4 | 211.6 | 227.4 | 261.1 | 352.0 |
Ton | 11.7 | 15.7 | 18.4 | 21.5 | 24.2 | 26.9 | 32.0 | 36.8 | 44.3 | 53.3 | 60.2 | 64.7 | 74.2 | 100.1 |
Rated cooling input power | kW | 12.50 | 17.60 | 20.50 | 24.30 | 27.50 | 30.20 | 35.00 | 40.90 | 47.90 | 60.10 | 67.50 | 72.30 | 82.60 | 110.60 |
Rated EER | W/W | 3.28 | 3.14 | 3.16 | 3.12 | 3.10 | 3.14 | 3.22 | 3.17 | 3.25 | 3.12 | 3.13 | 3.15 | 3.16 | 3.18 |
Rated heating capacity | kW | 45.6 | 61.3 | 71.9 | 84.1 | 94.6 | 105.2 | 125.0 | 143.7 | 172.9 | 208.0 | 234.9 | 252.4 | 289.8 | 390.7 |
Ton | 13.0 | 17.4 | 20.4 | 23.9 | 26.9 | 29.9 | 35.5 | 40.9 | 49.2 | 59.1 | 66.8 | 71.8 | 82.4 | 111.1 |
Rated heating input power | kW | 13.4 | 18.8 | 21.9 | 26.0 | 29.4 | 32.3 | 37.5 | 43.8 | 51.3 | 64.3 | 72.2 | 77.4 | 88.4 | 118.3 |
Rated COP | W/W | 3.4 | 3.3 | 3.3 | 3.2 | 3.2 | 3.3 | 3.3 | 3.3 | 3.4 | 3.2 | 3.3 | 3.3 | 3.3 | 3.3 |
Air supply | m3/h | 5400 | 10800 | 12600 | 15100 | 17100 | 18900 | 23000 | 26000 | 29100 | 32000 | 34500 | 37000 | 42500 | 51000 |
External static pressure | Pa | 200 | 200 | 200 | 250 | 250 | 250 | 300 | 300 | 300 | 350 | 350 | 420 | 420 | 500 |
Maximum operating current | A | 31.3 | 44.4 | 44.7 | 50 | 57 | 66.1 | 67.5 | 79.8 | 102.8 | 127 | 156 | 177 | 188 | 224 |
Capacity control | % | 100-50-25-0 |
Temperature control | | Microcomputer thermostat |
Compressor | | Hermetic high efficiency scroll compressor |
Refrigerant | | R410A & R407C |
Power supply | | 380-415V/3P/50Hz (380V/460V/3P/60Hz and 208V/1(3)Ph/60Hz as option) |
Protection devices | | High pressure protector, low pressure protector, compressor overheating protection, fusible plug,reverse-phase protection, exhaust overheat protection, compressor overcurrent protection, fan overcurrent protection,etc |
Filter | | Dismountable and compliant with the ASHEAE52-76 standards, dust intercept rate >95% |
Heat exchanger type | | High efficiency finned copper pipe heat exchanger |
Gas-fuel heater | | Optional parts, standard units are not configured |
Air exhauster | | Optional parts, standard units are not configured |
Economizer | | Optional parts, standard units are not configured |
Heat recovery | | Optional parts, standard units are not configured |
Fresh air | | Optional parts, standard units are not configured |
Noise level | dB(A) | 59 | 63 | 63 | 65 | 67 | 67 | 68 | 68 | 70 | 72 | 72 | 73 | 75 | 75 |
Dimension | Length | mm | 3330 | 3330 | 3330 | 3330 | 3330 | 3330 | 3937 | 3937 | 3937 | 3937 | 3937 | 12000 | 12000 | 12000 |
Width | mm | 2512 | 2512 | 2512 | 2512 | 2512 | 2512 | 2585 | 2585 | 2585 | 2585 | 2585 | 2540 | 2540 | 2540 |
Height | mm | 1511 | 1511 | 1511 | 1511 | 1511 | 1511 | 2455 | 2455 | 2455 | 2455 | 2455 | 2600 | 2600 | 2600 |
Weight | Net | kg | 875 | 935 | 1005 | 1230 | 1300 | 1510 | 1665 | 1910 | 2110 | 2480 | 2815 | 4800 | 5500 | 5800 |
Gross | kg | 998 | 1065 | 1150 | 1402 | 1510 | 1760 | 1945 | 2222 | 2525 | 2900 | 3230 | 5450 | 6230 | 6590 |
Notes:
1. Cooling condition: indoor air inlet dry bulb temperature 27ºC, wet bulb temperature 19ºC, outdoor air inlet dry bulb temperature 35ºC.
2. Heating condition: indoor air inlet dry bulb temperature 20ºC, outdoor air inlet dry bulb temperature 7ºC, wet bulb temperature 6ºC.
3. Gas heating and Electronic heating are for your option.
4. Constant temperature and humidity type, heat recovery and cooling only model are for your option
5. All specifications are subject to change without prior notice, please refer to nameplates for the most accurate specifications
Address:
No. 200, Technology Park, Jian Ye, Nanjing, Jiangsu, China
Business Type:
Manufacturer/Factory, Group Corporation
Business Range:
Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy, Packaging & Printing
Management System Certification:
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
Company Introduction:
Withair® Is a global provider of technical products and services for sustainability and resource management, specialize in heating & cooling system, air quality system and clean energy technology development and utilization, now it has three factories, manufacturing different kinds of products, and committed to providing the first-class products & system solutions for clients.
At Withair® , our aim is to support the growth, profit, and sustainability goals of our clients by delivering innovative solutions with n X value. We gain a deep understanding of our client′s needs and business objectives first and foremost by gaining and leveraging our technical knowledge, innovative thinking, and vast equipment resources. From heating & cooling solutions and air quality management, to energy performance and efficiency determination, Withair® Delivers the results.
Withair® Products & solutions combine utmost efficiency with minimum energy consumption and strict respect of the environment, the idea proved to be a winning one in just a few years, Withair® Became the leader in the sector!
Withair® Has highly effective professional team to service customers
Known for their professionalism and personal integrity, Withair′s highly skilled engineers, technicians, electricians, stable manufacturing workers, strict quality controller, and quick-reaction & professional after-service staff utilize their multi-disciplinary expertise in the creation and production of every solution.
Close cooperation among Withair′s design, production and service teams - who are located under one roof and linked by advanced computerized systems - enables the Company to supply the widest possible range of products - from single units to very large quantities - while assuring rapid delivery and competitive pricing.