Air Cooled Rooftop Heat Pump Unit with Economizers & Dampers

US$2,000.00 - 15,000.00 1 Piece (MOQ)
Port:
Nanjing, China
Production Capacity:
5000pieces/Year
Payment Terms:
L/C, T/T

Last Login Date:

May 16, 2025

Main Products:

Heat Pumps, Chillers, Rooftop Unit, Fan Coil Unit, Air Conditioners, Inverter Chiller

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
W05F Series
Certification
RoHS, CCC, ISO9001, CE
Working Medium
R410A or R407c
Heat Source Type
Air Source Heat Pump
Warranty
3 Years
Trademark
Withair®
Transport Package
Standard Export Package
Specification
Different
Origin
China
HS Code
84158300

Product Description

-- Product Description --

 

Withair® packaged rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, "no-strip screw" collars, and handled access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with environmentally (R-410A) refrigerant and are factory tested. Withair® packaged rooftop unit applicability is wide and used in shopping malls, hotels, factories, villas, commercial housing, office buildings, shops, hospitals and other places.

 

 

-- The Key Advantages Include --

 

 All model sizes share a common, compact cabinet in a single footprint for on-site flexibility.

 Installation time and costs are reduced by easy power and control wiring. All units are factory-wired, charged and tested prior to shipment.

 Gas and electric utility knockouts are provided on unit side and bottom for easy connections.

 Compressor is internally protected against high pressure and temperature.

 Units are engineered and built to be among the quietest models.

 Full-perimeter base rails are easily removable, yet provide a solid unit foundation.

 Durable finish, made of powder-painted, galvanized steel to meet 500-hour salt-spray test demands.

 Condensate drain is heavy-duty. 3/4" NPT connection is rigidly mounted for a proper fit and a tight seal.

 Condensate pan is non-corrosive, long-lasting and watertight.

 Convertible airflow design means no panel cutting is required, and no accessory panel is necessary.

 Heat exchangers are corrosion-resistant, with aluminized steel tubular construction for durability and long service life.

 Post-purge induced draft combustion exhausts combustion products from the heat exchanger to prolong heat exchanger life.

 Hot surface to pilot ignition provides faster, more reliable heat delivery.

 Secured service access ports are protected, externally mounted and reusable on both high and low lines.

 Complete line of field-installed accessories, including propane and high altitude conversion kits, economizers, single- and dual-enthalpy sensors and more.

 Evaporator coils are constructed with grooved copper tubes and enhanced for construction to improve heat transfer.

 Condenser coils are constructed of MicroChannel aluminum tubing and aluminum fins for durability and long-lasting efficient operation.

 Cooling operating range up to 52°C and down to -1°C.

 Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement.

 Access panels with easy grip handles and tool-less filter access door

 Belt drive evaporator-fan motor and pulley combinations available on all three phase models to meet any application

 Field convertible from vertical to horizontal airflow for slab mounting.

 Dependable time/temperature defrost board and logic.

 Loss of charge, freeze protection, and high-pressure switches

 Totally enclosed condenser motors with permanently lubricated bearings.

 Permanently lubricated evaporator-fan motor.



 

1. Multi-compressors system - provide up to 4 grades of refrigeration capacity regulation, optional variable capacity digital scroll compressor can further improve the equipment energy saving and control accuracy.

2. Double layer board gold structure -- polyamine foam double layer board gold structure pioneered by yilong.The highest thermal resistance in the industry is 2.8m2ºC/w.

3. Electronic expansion valve - provides the most accurate superheat control (1ºC) while reducing equipment failure rate.

4. Controller - optional PLC programmable controller improves field control adaptability and makes network connection faster.

5. Heat exchanger - the world's first oval tube heat exchanger to greatly improve the energy saving level.

6. Reheater (optional) - reheat is provided through waste heat of condenser without electric heating.

7. Heat recovery wheel (optional) - there are two options, sensible heat and total heat, to absorb the energy in the exhaust air.

8. Enthalpy difference controller (optional) - when the outdoor enthalpy value is lower than the indoor enthalpy value, the compressor is closed and the outdoor natural air is utilized cooling room environment.

9. Secondary air return (side) - humidity control through secondary air return is the most energy-saving humidity control solution.

10. Gas heating (optional) - gas heating can be used in winter to provide stable heating.

11. High efficiency fan motor - straight connected vortex free case backward tilt fan greatly improves fan efficiency.

12. Types selection - air - cooled type or water - cooled type for option.

 

Withair's patent: Air volume and compressor capacity automatically matching


 

Withair's Rooftop Unit can provide up to 7 levels of air volume regulation, greatly improving the energy efficiency of the equipment.For example, when indoor load is low, only one compressor is working, at this time, the air supply volume will be automatically reduced to 15-20% of the total air volume to achieve the energy saving goal.

When the indoor load increases, for example, two compressors are needed to put into operation, the air supply will automatically increase to match the cooling capacity.

-- Product Features --


 

-- The Directions of Air Supply & Air Inlet --

 

Multiple optional air supply methods, so that Withair Rooftop air conditioner can adapt to a variety of building conditions.

Whether indoor or outdoor, whether the roof or the ground, it can be a good design layout.


 

-- Rapid Product Customization Services --

 

Customer's personalized demand for Rooftop Unit  is the design concept of Withair. our each Rooftop Unit can be customized according

to the customer's special requirements.Our engineers will quickly design each personalized roof machine, including the structure, function

and control can be customized.



 

Up To 100% Fresh Air DC Inverter Rooftop Unit (1)

Model  W05R1- 10RFI14RFI18RFI21RFI25RFI32RFI43RFI50RFI65RFI77RFI88RFI106RFI
CoolingCapacitykW10.613.917.821.025.232.043.050.063.576.988.7106.0
Ton3.04.05.16.07.29.112.214.218.121.925.230.1
Input powerkW3.104.035.295.987.379.1912.1114.5018.3921.9625.3231.29
EERW/W3.423.453.363.513.423.483.553.453.453.503.503.39
HeatingCapacitykW11.815.419.823.328.035.547.755.570.585.498.5117.7
Ton3.34.45.66.68.010.113.615.820.024.328.033.5
Input powerkW3.24.25.56.27.79.612.615.119.122.826.332.5
COPW/W3.63.73.63.73.63.73.83.73.73.73.73.6
Air supply (Fresh air)m3/h8001,0001,2501,4001,8002,2003,0003,5004,2005,2005,9007,200
External static pressurePa200200200200220220250250250270300300
Maximum operating   currentA1620252532506080100100125160
Capacity control Continuous
Temperature control Microcomputer thermostat
Compressor DC Inverter Hermetic high   efficiency scroll compressor
Refrigerant  R410A
Power supply 380-415V/3P/50Hz   (380V/460V/3P/60Hz and 208V/1(3)Ph/60Hz as an option)
Protection devices High   pressure protector, low pressure protector, compressor overheating   protection, fusible plug,
     reverse-phase protection, exhaust   overheat protection, compressor overcurrent protection, fan overcurrent protection,   etc
Filter Dismountable and compliant   with the ASHEAE52-76 standards, dust intercept rate >95%
Heat exchanger type High efficiency finned   copper pipe heat exchanger
Gas-fuel   heater  Optional parts,  standard units are not configured
Air exhauster Optional parts,  standard units are not configured
Economizer Optional parts,  standard units are not configured
Heat recovery Optional parts,  standard units are not configured
Noise leveldB(A)525454565860616364656768
Air outlet sizemm262*300225*860225*860225*860341*395341*395341*395479*489404*471404*471478*557478*557
DimensionLengthmm1,1041,0541,1801,1041,6751,6751,9702,2252,2252,2252,7902,790
Widthmm8718039209601,3951,3951,5551,6351,8601,8601,8601,860
Heightmm1,0341,1831,1831,1831,4651,4651,9501,9502,1502,1502,1502,150
WeightNetkg1721902202354435606628008519861,1251,233
Grosskg1962182552714756127238729331,0851,3101,428

Notes: 

1. Cooling condition: indoor air inlet dry bulb temperature 27ºC, wet bulb temperature 19ºC, outdoor air inlet dry bulb temperature 35ºC. 

2. Heating condition: indoor air inlet dry bulb temperature 20ºC, outdoor air inlet dry bulb temperature 7ºC, wet bulb temperature 6ºC.

3. Constant temperature and humidity type,  100% fresh air and partial fresh air, heat recovery and cooling only model are for your option. 

4. All specifications are subject to change without prior notice, please refer to nameplates for the most accurate specifications

 

DC Inverter Rooftop Unit with 100%Fresh Air (2)

Model  W05R1- 139RFI176RFI186RFI203RFI
CoolingCapacitykW139.0176.3186.5203.4
Ton39.550.153.057.8
Input powerkW40.8050.9054.6060.50
EERW/W3.413.463.423.36
HeatingCapacitykW155.7197.4208.8227.8
Ton44.356.159.464.8
Input powerkW42.452.956.862.9
COPW/W3.73.73.73.6
Air supply (Fresh air)m3/h9,20011,50012,30014,000
External static pressurePa320350350400
Maximum operating currentA200250250300
Capacity control Continuous
Temperature control Microcomputer   thermostat
Compressor DC   Inverter Hermetic high efficiency scroll compressor
Refrigerant  R410A
Power supply 380-415V/3P/50Hz   (380V/3P/60Hz and 208V/1(3)Ph/60Hz as an option)
Protection devices High   pressure protector, low pressure protector, compressor overheating   protection, fusible plug, reverse-phase protection, exhaust overheat   protection, compressor overcurrent protection, fan overcurrent protection,   etc
Filter Dismountable   & compliant with the ASHEAE52-76 standards, dust intercept rate >95%
Heat exchanger type High   efficiency finned copper pipe heat exchanger
Gas-fuel   heater  Optional   parts,  standard units are not   configured
Air exhauster Optional   parts,  standard units are not   configured
Economizer Optional   parts,  standard units are not   configured
Heat recovery Optional   parts,  standard units are not   configured
Noise leveldB(A)74767779
Air outlet sizemm638*638638*6381600*8001600*800
DimensionLengthmm4,0004,0004,5004,500
Widthmm2,3002,3002,3002,300
Heightmm2,1202,1202,1202,120
WeightNetkg1,9002,1902,2702,650
Grosskg2,3502,6602,7103,135

Notes: 

1. Cooling condition: indoor air inlet dry bulb temperature 27ºC, wet bulb temperature 19ºC, outdoor air inlet dry bulb temperature 35ºC. 

2. Heating condition: indoor air inlet dry bulb temperature 20ºC, outdoor air inlet dry bulb temperature 7ºC, wet bulb temperature 6ºC.

3. Constant temperature and humidity type,  100% fresh air and partial fresh air, heat recovery and cooling only model are for your option. 

4. All specifications are subject to change without prior notice, please refer to nameplates for the most accurate specifications

Send your message to this supplier
Mr. Jed Ji

Post a Sourcing Request Now

People who liked this also liked
Get Quick Quotes